Vibration sensor

Consult immediately
Reservation Now
Detail

Vibration sensor 3300 Series(5/8/11mm)   Bently

5mm Proximity Probe.

Specifications:Unless otherwise noted, the following specifications are for a proximity transducer system between +18℃ and +27℃ (+64℉ to+80℉) with a -24 Vdc power supply, a 10 kW load, an AlSI 4140 steel target, and a probe gapped at 1.27 mm (50 mils).

Probe Temperature Range: -35℃ to +177℃(-31℉ to +351℉)

Over probe temperature range of -35°C to +177°C (-31F to +350°F),the incremental scale factor remains within ±l0% of 7.87V/mm (200 mV/mil) and the deviation from the best fit straight line remains within ±0.076 mm (±3mils).

Shaft Diameter:Minimum 50.8mm(2 in), Recommended minimum 76.2mm(3 in)

Frequency Response: 0 to 10 kHz: +0,-3 dB, with up to 305 meters (1000 feet) of field wiring.


8mm Proximity Probe.

Specifications:Unless otherwise noted, the following specifications are for a 3300 XL 8 mm Proximitor Sensor, extension cable and 8 mm probe between +18℃ and +27℃   (+64℉ to +80℉) at a maximum altitude of 2000 meters,with a -24 Vdc power supply, a 10 kΩ load, an AISI 4140 steel target, and a probe gapped at1.27 mm (50 mils). Performance characteristics apply to systems that consist solely of 3300 XL 8mm components. The system accuracy and interchangeability specifications do not apply to transducer systems that are calibrated to any target other than our AISI 4140 steel target.

Probe Temperature Range: -35℃ to +120℃(-31℉ to +248℉)

Over a probe temperature range of -35℃ to +120℃(-31℉ to +248℉) with the Proximitor sensor and extension cable between 0℃ to +45℃(+32℉ to+ 113℉), the ISF remains within

±10% of 7.87 V/mm (200 mV/mil) and the DSL remains within ±0.076 mm(±3 mils)

Shaft Diameter:Minimum 50.8mm(2 in), Recommended minimum 76.2mm(3 in)

11mm Proximity Probe.

Unless otherwise noted, the following specifications are for a 3300 XL 11 mm Proximitor Sensor, extension cable and probe between 0°C and +45°C (+32°F to +113°F) at a maximum altitude of 2000m, with a -24 Vdc power supply, a 10 kΩ load, our supplied AIsI 4140 steel target that is 31 mm (1.2 in) diameter or larger, and a probe gap of 2.5 mm (100mils). The system accuracy and interchangeability specifications do not apply when using a transducer system calibrated to any target other than our AISI 4140 steel target.

Probe Temperature Range: -52℃ to +177℃(-62℉ to +351℉)

Over a probe temperature range of -35℃ to +120℃(-31℉ to +248℉) with the Proximitor sensor and extension cable between 0℃ to +45℃(+32℉ to+ 113℉), the ISF remains within

±25% of 3.94 V/mm (100 mV/mil) and the DSL remains within ±0.51 mm(±20 mils)and the

extended range DSL remains within ±0.59 mm(±23 mils)。



Phone:+86 18570737777
Whatsapp:+86 18570737777
WeChat
Scan QRcode
Email:Sales@influx.ltd